Tools & Calculators › AI assistants
Use QRPedia in your AI assistant
QRPedia runs an MCP server. Your AI assistant can call the calculator engines this site uses, then quote their numbers and sources instead of guessing. It is free and read-only, with no sign-up.
https://qrpedia.com/mcpSet up your assistant
Swipe for more assistants →
Claude
- Custom connectors are available on Free, Pro, Max, Ultra, Team, and Enterprise plans. A Free plan is limited to one custom connector. On a Pro or Max plan, open Customize > Connectors, choose + Add, then Add custom connector. On a Team or Enterprise plan, an Owner or Primary Owner opens Organization settings > Connectors, chooses Add, then Custom, then Web. On an Enterprise plan, a custom role with Manage access to Libraries can add one too.
- Add QRPedia as a remote MCP server with the URL
https://qrpedia.com/mcp. No sign-in or API key. - In a chat, open the + button, then Connectors, and turn QRPedia on. Open Search and tools. That menu lists the connector’s tools. You should see the fifteen tools in the table on this page.
Name: QRPedia
Remote MCP server URL: https://qrpedia.com/mcp
Authentication: No sign inChatGPT
- In ChatGPT on the web, open Plugins. Select the plus button, then Add custom MCP server.
- Add QRPedia as a remote MCP server with the URL
https://qrpedia.com/mcp. No sign-in or API key. - Review the tools the server returns, confirm the risk warning, then Create as a plugin and install it. The app details page lists the tools and can refresh them. You should see the fifteen tools in the table on this page.
Name: QRPedia
Server URL: https://qrpedia.com/mcp
Authentication: No authenticationCursor
- Create
.cursor/mcp.jsonin the project, or~/.cursor/mcp.jsonfor every project. Customize in the sidebar also manages MCP servers. - Add QRPedia as a remote MCP server with the URL
https://qrpedia.com/mcp. No sign-in or API key. - In chat, tools from the server are listed under Available Tools. Customize can enable or disable the server. You should see the fifteen tools in the table on this page.
{
"mcpServers": {
"qrpedia": {
"url": "https://qrpedia.com/mcp"
}
}
}VS Code
- With Copilot selected, run Chat: Open Customizations and select MCP Servers. Select Add Server (+) in the User group, then HTTP (HTTP or Server-Sent Events). Enter the endpoint and a server id, then choose Global > Copilot Global, or a workspace
.mcp.json. - Add QRPedia as a remote MCP server with the URL
https://qrpedia.com/mcp. No sign-in or API key. - Open the MCP Servers list and review the available tools for this server. You should see the fifteen tools in the table on this page.
{
"mcpServers": {
"qrpedia": {
"type": "http",
"url": "https://qrpedia.com/mcp",
"tools": ["*"]
}
}
}Claude Code
- From the project directory, run
claude mcp add --transport http qrpedia https://qrpedia.com/mcp, or create.mcp.jsonas in the snippet. A URL entry needs"type": "http". - Add QRPedia as a remote MCP server with the URL
https://qrpedia.com/mcp. No sign-in or API key. - Run
claude mcp listand confirm the server is connected. In a session,/mcpshows the tool count beside the server. It should show 15 tools.
{
"mcpServers": {
"qrpedia": {
"type": "http",
"url": "https://qrpedia.com/mcp"
}
}
}Setup steps checked against each vendor’s documentation on 13 November 2026.
What it does
It does
- Gives the same numbers as the site, from the same engine files.
- Puts its sources (references) in every calculator result.
- Adds the disclaimer the tool returns. Coil and core tools end with “Design estimate from the cited sources. Measure the finished part; permeability, wire placement, and lead length move the value.” A filter design ends with “These values assume ideal, lossless parts. Real inductors have finite Q, which adds passband loss and rounds the Chebyshev ripple, so use the highest-Q inductors practical (for example powdered-iron toroids of a mix suited to the frequency). Use stable, low-loss capacitors such as C0G/NP0 ceramic or silver mica, with a voltage rating of about twice the peak RF voltage across them. In a transmitter harmonic filter, that voltage is set by the power level and impedance.”
It does not
- Save designs, post feedback or change anything.
- Run KiCad or ngspice, or make PDFs or plot images.
- Do any math the site does not.
- Offer prompt templates. Those may come with v1.1.
Tools
Fifteen tools: the nine from v1.0, plus cascade_receiver, maidenhead_grid, match_impedance and design_balun from v1.1, and filter_tolerance and design_crystal_ladder.
| Tool | What it does | Main inputs | On the site |
|---|---|---|---|
| Search | |||
search_qrpedia | Find calculators, reference pages, articles, Circuit Library entries and cores, ranked like the site search box. | query | Site search |
| Coils and cores | |||
toroid_turns | Turns for an inductance, or inductance for a number of turns, on a named core, with single-layer fit and the wire length to cut. | core, mode, inductance, unit, turns, awg | Iron Powder Toroid Turns |
filter_windings | Pick a core, mix, turns and wire for every inductor in a design at a given power, with the site's flags. | filter, power_w, coil_type, awg | LC Filter Designer |
air_wound_coil | Size a single-layer air-wound coil for a target inductance. | inductance_h, power_w | LC Filter Designer |
core_q | Estimate the unloaded Q of an iron-powder toroid of mix 2 or 6 at a frequency. | mix, frequency_hz | LC Filter Designer |
list_cores | List cores with AL, size and datasheet link, filtered by family, mix or size. | family, mix, max_od_in, limit, cursor | Toroid cores |
| Filters | |||
design_lc_filter | Design a passive LC low-pass, high-pass, band-pass or band-stop filter with the element values and cautions the LC Filter Designer shows. | type, response, order, fc_hz, f1_hz, f2_hz, ripple_db, stopband_db, rs_ohm, rl_ohm, form, round_to | LC Filter Designer |
filter_response heavy · 10/min | S21, S11, return loss and group delay for a design, with optional finite coil Q for band-pass loss. | filter, f_start_hz, f_stop_hz, points, spacing, coil_q | LC Filter Designer |
filter_tolerance heavy · 10/min | How 1, 2, 5 and 10 percent part tolerances spread an LC filter response and its −3 dB edges. A seeded uniform Monte Carlo plus the all-low and all-high corners (QRPedia design rule). | filter, tol_l_pct, tol_c_pct, trials, seed | LC Filter Designer |
export_filter | The same SPICE netlist, LTspice schematic, response CSV or parts CSV the site downloads. | filter, format, sweep | LC Filter Designer |
| Receivers | |||
cascade_receiver | Gain, noise figure, MDS and IP3 for a receiver chain. | blocks, bw_hz | Cascaded Receiver Calculator |
| Grid locators | |||
maidenhead_grid | Convert between a Maidenhead locator and latitude/longitude, with the cell bounds and size. | grid, lat, lon, precision | Maidenhead Grid Locator |
| Matching | |||
match_impedance | Design L, Pi and Tee impedance matching networks, with part values, SWR bandwidth, stress and toroid or air-wound coils (EMRFD pp. 3.30-3.31). | f_hz, zs, zl, z0, topology, form, q, q_side, q_min, power_w, series, qu_l, qu_c | Impedance Matching Calculator |
| Baluns | |||
design_balun | Design a broadband transformer or balun on a ferrite core, with turns, fit, cut length and a power-stress check (Sevick, Transmission Line Transformers; Fair-Rite; ARRL Handbook 2023, Table 22.44). | type, z_ohm, side, core, awg, f_low_hz, f_high_hz, m, k, power_w | Balun & Broadband Transformer Designer |
| Crystal filters | |||
design_crystal_ladder heavy · 10/min | A Cohn or Butterworth/Chebyshev crystal ladder from measured motional parameters, with mesh capacitors, the end match, the loss estimate and the bandwidth check (EMRFD ch. 3, Zverev sec. 6.10, QEX June 1995 Fig 8). | f_hz, bandwidth_hz, lm_h, qu, co_f, shape, n, rin_ohm, rout_ohm, raise, comp | Crystal Ladder Filter |
The tool names, their order, the heavy pill and these input names are checked against the server’s tools/list.
Limits
- The heavy tools share 10 a minute:
filter_response,filter_toleranceanddesign_crystal_ladder. - Over a limit, the server answers 429 with a Retry-After time.
- Each call has 2 s to finish. Requests are capped at 16 KB and responses at 256 KB.
Privacy
- No sign-upNo account, no sign-in and no API key.
- Read-onlyThe tools only compute and look things up. Nothing you send is saved.
- Counts-only logsOne line a minute: calls per tool, ok and error counts and timing. The MCP server's log has no IPs, no inputs, no user agents.
- No third partiesNo AI model inside the server and no calls to other services.
qrpedia.com's web server keeps no access log, so requests to /mcp are not recorded one by one. The MCP server itself logs only per-minute call counts and timings for each tool, never IP addresses or tool arguments. Error messages go to the server's system log; a rare one, such as a reply cut off mid-stream, can include the IP address and request headers, but never cookies or authorization headers.
Examples
“How many turns do I need on a T50-2 for 1 µH?”
toroid_turns{ "core": "T50-2", "mode": "forward", "inductance": 1, "unit": "µH" }14 turns for 1 µH on a T50-2. exact_turns 14.29. actual_inductance 0.96 µH (error_pct -4). max_single_layer_turns 39, fits_single_layer true. cut_length_cm 30, cut_length_in 12. Nominal value; AL tolerance ±5% (Micrometals datasheet).
See it on the site: https://qrpedia.com/calculators/iron-powder-toroid-calculator.html?core=T50-2
References returned with the result:
- https://datasheets.micrometals.com/T50-2-DataSheet.pdf
- https://www.baewire.com/v/vspfiles/files/HeavyWireChart.pdf
Every result ends: “Design estimate from the cited sources. Measure the finished part; permeability, wire placement, and lead length move the value.”
“Design a 5 W low-pass filter for 40 m and tell me how to wind the coils.”
design_lc_filter, then filter_windings{"type": "lowpass", "response": "chebyshev", "order": 5, "fc_hz": 7000000, "ripple_db": 0.1, "rs_ohm": 50}{"filter": {"response": "chebyshev", "type": "lowpass", "order": 5, "fc": 7000000, "rippleDb": 0.1, "rs": 50}, "power_w": 5, "coil_type": "auto"}A 5th-order 0.1 dB Chebyshev low-pass. Cutoff 7 MHz, 50 ohm on both sides. C1 is 521 pF shunt, L2 is 1.56 µH series, C3 is 898 pF shunt, L4 is 1.56 µH series, and C5 is 521 pF shunt. The 3 dB frequency is 7.94 MHz.
At 5 W, L2 and L4 each wind on a T50-2, 18 turns. The target is 1.56 µH and the core gives 1.59 µH, 1.8% high. Each winding fits one layer, and the cut length is 15 in. The rating is provisional: ratings assume key-down carrier in still air, 25 °C rise, copper loss not included; loss above 10 MHz extrapolated. Peak flux is near the Amidon limit.
References returned with the design:
- g-values: Matthaei, Young & Jones (1964) closed form, checked against the RF Cafe tables (https://www.rfcafe.com/references/electrical/butter-proto-values.htm and https://www.rfcafe.com/references/electrical/cheby-proto-values.htm, fetched 2026-10-28). Coupled-resonator k and q are computed from g (k = 1/sqrt(g_i g_{i+1}), q = g0 g1), converted to the 3 dB basis, and checked against Zverev sec. 6.10 Tables 6.10-1 ff., pp. 341-351, q0 = infinity rows.
- Zverev's Handbook of Filter Synthesis (1967) sec. 5.8 pp. 168-289 and sec. 6.10
- EMRFD for the coupled-resonator starting L (L = 10/F; Hayward, Campbell & Larkin, Experimental Methods in RF Design, ARRL, 1st ed. (2003), p. 3.14)
- Hayward, Campbell & Larkin, Experimental Methods in RF Design, ARRL, 1st ed. (2003), p. 3.10, credited there to Cohn
References returned with the windings:
- https://datasheets.micrometals.com/T50-2-DataSheet.pdf
- Mix selection (mix 2 below 10 MHz, mix 6 from 10 MHz) is a QRPedia design rule based on Amidon's resonant-circuit best-Q ranges.
- A toroid core is chosen only if it gives at least 5 turns; when none does, the result is flagged few-turns (QRPedia design rule).
- Minimum core size follows carrier power (QRPedia design rule).
- https://elnamagnetics.com/wp-content/uploads/library/Micrometals/Iron_Powder_Core_Selection_for_RF_Power_Applications.pdf
- https://www.amidoncorp.com/product_images/specifications/1-35.pdf
- https://www.amidon.de/contents/de/d584_01.html
- https://www.baewire.com/v/vspfiles/files/HeavyWireChart.pdf
See it on the site: https://qrpedia.com/calculators/lc-filter-designer.html
Every result ends: design_lc_filter ends “These values assume ideal, lossless parts. Real inductors have finite Q, which adds passband loss and rounds the Chebyshev ripple, so use the highest-Q inductors practical (for example powdered-iron toroids of a mix suited to the frequency). Use stable, low-loss capacitors such as C0G/NP0 ceramic or silver mica, with a voltage rating of about twice the peak RF voltage across them. In a transmitter harmonic filter, that voltage is set by the power level and impedance.” filter_windings ends “Design estimate from the cited sources. Measure the finished part; permeability, wire placement, and lead length move the value.”
“Which ferrite cores come in mix 43?”
list_cores{ "family": "ferrite", "mix": "43" }Ferrite mix 43. This is the full list.
- FT-23-43, 0.234 in outside diameter, A_L 158. https://fair-rite.com/printer_friendly_datasheet.php?part=5943000101
- FT-37-43, 0.374 in outside diameter, A_L 350. https://fair-rite.com/printer_friendly_datasheet.php?part=5943000201
- FT-50-43, 0.500 in outside diameter, A_L 440. https://fair-rite.com/printer_friendly_datasheet.php?part=5943000301
- FT-50A-43, 0.500 in outside diameter, A_L 480. https://fair-rite.com/printer_friendly_datasheet.php?part=5943001101
- FT-50B-43, 0.500 in outside diameter, A_L 965. https://fair-rite.com/printer_friendly_datasheet.php?part=5943001901
- FT-82-43, 0.827 in outside diameter, A_L 470. https://fair-rite.com/printer_friendly_datasheet.php?part=5943000601
- FT-100-43, 1.000 in outside diameter, A_L 500. https://fair-rite.com/printer_friendly_datasheet.php?part=5943001301
- FT-114-43, 1.142 in outside diameter, A_L 510. https://fair-rite.com/printer_friendly_datasheet.php?part=5943001001
- FT-114A-43, 1.142 in outside diameter, A_L 950. https://fair-rite.com/printer_friendly_datasheet.php?part=5943001201
- FT-125-43, 1.250 in outside diameter, A_L 775. https://fair-rite.com/printer_friendly_datasheet.php?part=5943001701
- FT-140-43, 1.400 in outside diameter, A_L 885. https://fair-rite.com/printer_friendly_datasheet.php?part=5943002701
- FT-240-43, 2.402 in outside diameter, A_L 1075. https://fair-rite.com/printer_friendly_datasheet.php?part=5943003801
References returned with the result:
https://fair-rite.com/printer_friendly_datasheet.php?part=<PART>https://fair-rite.com/product/toroids-<PART>/
See it on the site: https://qrpedia.com/calculators/ferrite-toroid-calculator.html
Every result ends: “Design estimate from the cited sources. Measure the finished part; permeability, wire placement, and lead length move the value.”
Every number has a source
Every calculator result carries its references, the engine version and a link to the same calculator on this site.
Check the connection
From a terminal, list the tools. The command form comes from the MCP Inspector docs.
npx @modelcontextprotocol/inspector --cli https://qrpedia.com/mcp --transport http --method tools/listChecked on 17 November 2026 with a local tools/list against a server from this repo. The server listed, in order: search_qrpedia, toroid_turns, filter_windings, air_wound_coil, core_q, list_cores, design_lc_filter, filter_response, filter_tolerance, export_filter, cascade_receiver, maidenhead_grid, match_impedance, design_balun, design_crystal_ladder.