Magnet Wire Tables
Enameled copper magnet wire, #10 to #40 AWG. Diameters, resistance and area are computed from the AWG definition and copper resistivity, then checked against a NEMA MW 1000 manufacturer table.
Copper magnet wire by AWG
Bare diameter: d = 0.005 in × 92(36−n)/39. Resistance at 20 °C from annealed copper at 100% IACS, ρ = 1.7241 × 10−8 Ω·m (10.371 Ω·cmil/ft). Heavy-build overall diameter is the NEMA MW 1000-2020 nominal from MWS Wire's Copper Magnet Wire Data. Turns per inch is computed as 1 ÷ heavy-build diameter, for one close-wound layer.
| AWG | Bare (in) | Bare (mm) | Heavy OD (in) | Ω/1000 ft | Ω/km | Area (cmil) | Turns/in (computed) | A at 200 A/cm²* | A at 400 A/cm²* |
|---|---|---|---|---|---|---|---|---|---|
| 10 | 0.1019 | 2.588 | 0.105 | 0.9988 | 3.277 | 10,383 | 9.49 | 10.5 | 21.0 |
| 11 | 0.09074 | 2.305 | 0.0942 | 1.260 | 4.132 | 8,234 | 10.6 | 8.34 | 16.7 |
| 12 | 0.08081 | 2.053 | 0.0842 | 1.588 | 5.211 | 6,530 | 11.9 | 6.62 | 13.2 |
| 13 | 0.07196 | 1.828 | 0.0754 | 2.003 | 6.571 | 5,178 | 13.3 | 5.25 | 10.5 |
| 14 | 0.06408 | 1.628 | 0.0675 | 2.525 | 8.285 | 4,107 | 14.8 | 4.16 | 8.32 |
| 15 | 0.05707 | 1.450 | 0.0603 | 3.184 | 10.45 | 3,257 | 16.6 | 3.30 | 6.60 |
| 16 | 0.05082 | 1.291 | 0.0539 | 4.015 | 13.17 | 2,583 | 18.6 | 2.62 | 5.23 |
| 17 | 0.04526 | 1.150 | 0.0482 | 5.063 | 16.61 | 2,048 | 20.7 | 2.08 | 4.15 |
| 18 | 0.04030 | 1.024 | 0.0431 | 6.385 | 20.95 | 1,624 | 23.2 | 1.65 | 3.29 |
| 19 | 0.03589 | 0.9116 | 0.0386 | 8.051 | 26.41 | 1,288 | 25.9 | 1.31 | 2.61 |
| 20 | 0.03196 | 0.8118 | 0.0346 | 10.15 | 33.31 | 1,022 | 28.9 | 1.04 | 2.07 |
| 21 | 0.02846 | 0.7229 | 0.0310 | 12.80 | 42.00 | 810.1 | 32.3 | 0.821 | 1.64 |
| 22 | 0.02535 | 0.6438 | 0.0276 | 16.14 | 52.96 | 642.4 | 36.2 | 0.651 | 1.30 |
| 23 | 0.02257 | 0.5733 | 0.0249 | 20.36 | 66.78 | 509.5 | 40.2 | 0.516 | 1.03 |
| 24 | 0.02010 | 0.5106 | 0.0223 | 25.67 | 84.21 | 404.0 | 44.8 | 0.409 | 0.819 |
| 25 | 0.01790 | 0.4547 | 0.0199 | 32.37 | 106.2 | 320.4 | 50.3 | 0.325 | 0.649 |
| 26 | 0.01594 | 0.4049 | 0.0178 | 40.81 | 133.9 | 254.1 | 56.2 | 0.258 | 0.515 |
| 27 | 0.01420 | 0.3606 | 0.0161 | 51.47 | 168.9 | 201.5 | 62.1 | 0.204 | 0.408 |
| 28 | 0.01264 | 0.3211 | 0.0144 | 64.90 | 212.9 | 159.8 | 69.4 | 0.162 | 0.324 |
| 29 | 0.01126 | 0.2859 | 0.0130 | 81.83 | 268.5 | 126.7 | 76.9 | 0.128 | 0.257 |
| 30 | 0.01003 | 0.2546 | 0.0117 | 103.2 | 338.5 | 100.5 | 85.5 | 0.102 | 0.204 |
| 31 | 0.008928 | 0.2268 | 0.0104 | 130.1 | 426.9 | 79.70 | 96.2 | 0.0808 | 0.162 |
| 32 | 0.007950 | 0.2019 | 0.00940 | 164.1 | 538.3 | 63.21 | 106 | 0.0641 | 0.128 |
| 33 | 0.007080 | 0.1798 | 0.00840 | 206.9 | 678.8 | 50.13 | 119 | 0.0508 | 0.102 |
| 34 | 0.006305 | 0.1601 | 0.00750 | 260.9 | 856.0 | 39.75 | 133 | 0.0403 | 0.0806 |
| 35 | 0.005615 | 0.1426 | 0.00670 | 329.0 | 1,079 | 31.52 | 149 | 0.0319 | 0.0639 |
| 36 | 0.005000 | 0.1270 | 0.00600 | 414.8 | 1,361 | 25.00 | 167 | 0.0253 | 0.0507 |
| 37 | 0.004453 | 0.1131 | 0.00550 | 523.1 | 1,716 | 19.83 | 182 | 0.0201 | 0.0402 |
| 38 | 0.003965 | 0.1007 | 0.00490 | 659.6 | 2,164 | 15.72 | 204 | 0.0159 | 0.0319 |
| 39 | 0.003531 | 0.08969 | 0.00430 | 831.8 | 2,729 | 12.47 | 233 | 0.0126 | 0.0253 |
| 40 | 0.003145 | 0.07987 | 0.00380 | 1,049 | 3,441 | 9.888 | 263 | 0.0100 | 0.0200 |
*Current at a winding current density, not an ampacity rating. Transformer and inductor designers size windings by current density. McLyman gives the rule of thumb 500 circular mils per amp ≈ 400 A/cm² and 1000 circular mils per amp ≈ 200 A/cm² (Transformer and Inductor Design Handbook, 3rd ed., ch. 4, PDF). The columns are bare copper area × current density, and agree within 3% with the 200 and 400 A/cm² columns of the Magnetics Inc. Wire Table.
Rules of thumb that follow from the AWG formula: every 3 gauges halves the area and doubles the resistance, and every 6 gauges halves the diameter. #10 is about 1 Ω per 1000 ft (MWS: 0.9988 Ω).